Skip to content

Revert LPP Failsafe values back to positive values in the examples#214

Merged
sthelen-enqs merged 1 commit into
devfrom
188-update-controlboxhems-examples-positive_failsafe_limits
Apr 15, 2026
Merged

Revert LPP Failsafe values back to positive values in the examples#214
sthelen-enqs merged 1 commit into
devfrom
188-update-controlboxhems-examples-positive_failsafe_limits

Conversation

@uhl
Copy link
Copy Markdown
Contributor

@uhl uhl commented Apr 14, 2026

Per the spec, the values are always >= 0 because their name already indicates the production direction Only the APPL value itself (the LoadLimit.Value in SetProductionLimit and WriteProductionLimit) remains <= 0 (-10000 in HEMS, -100 in controlbox), since that's the SignDependentAbsValueLimit where sign matters.

Per the spec, the values are always >= 0 because their name already indicates the production direction
Only the APPL value itself (the LoadLimit.Value in SetProductionLimit and WriteProductionLimit) remains <= 0 (-10000 in HEMS, -100 in controlbox), since that's the SignDependentAbsValueLimit where sign matters.
@sthelen-enqs
Copy link
Copy Markdown
Contributor

LGTM, thanks

@sthelen-enqs sthelen-enqs self-requested a review April 15, 2026 07:17
@sthelen-enqs sthelen-enqs added documentation Improvements or additions to documentation eebus spec Topics dealing with the EEBUS specification labels Apr 15, 2026
@sthelen-enqs sthelen-enqs added this to the Version 0.8 milestone Apr 15, 2026
@sthelen-enqs sthelen-enqs merged commit 1a17729 into dev Apr 15, 2026
7 checks passed
@sthelen-enqs sthelen-enqs deleted the 188-update-controlboxhems-examples-positive_failsafe_limits branch April 15, 2026 07:18
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment