A bridge for multiple "smart meters" (eg. electricity meters that can be read out digitally through serial or modbus) to a MQTT broker
MQTT variables
MQTT_BROKER_ADDRESS(defaults tolocalhost)MQTT_BROKER_PORT(defaults to1883)MQTT_TOPIC_PREFIX(defaults tosmart-meter)MQTT_QOS(defaults to0)MQTT_RETAIN(defaults totrue)
Smart-meter variables
SMART_METER_TYPE(available types:dts353f,sdm72dm,p1)
Other smart-meter specific variables need to be present depending on which smart meter is connected. To figure out which environment variables are required by your smart meter, fill out only the SMART_METER_TYPE environment variable and look for errors when running the Docker image. Additional variables might have different defaults depending on the smart meter type, and include:
SMART_METER_CONNECTION_TYPESMART_METER_SERIAL_PORTSMART_METER_SERIAL_BAUDRATESMART_METER_SERIAL_BYTESIZESMART_METER_SERIAL_PARITYSMART_METER_SERIAL_STOPBITSSMART_METER_SERIAL_TIMEOUTSMART_METER_TCP_ADDRESSSMART_METER_TCP_PORTSMART_METER_MEASUREMENT_INTERVAL- See
smart_meter/smart_meter_factory.pyfor all smart-meter environment variables and information on how they are used.
P1, most Dutch smart electricity meters support this serial-based protocolDTS353F, a modbus electricity meter by YTLSDM72D-M, a modbus electricity meter by Eastron
Depending on which parameters are exposed by the electricity meter, it will publish to the following topics:
{prefix}/l1|l2|l3/voltage: voltage in V{prefix}/l1|l2|l3/amperage: current in A{prefix}/l1|l2|l3/power: power in kW{prefix}/l1|l2|l3/energy: energy in kWh{prefix}/l1|l2|l3/energy/delivery: energy delivery in kWh{prefix}/l1|l2|l3/energy/erdelivery: energy redelivery in kWh{prefix}/power: total power in kW{prefix}/energy: total energy in kWh{prefix}/energy/delivery: total energy delivery in kWh{prefix}/energy/redelivery: total energy redelivery in kWh{prefix}/frequency: grid frequency in Hz{prefix}/tariff: current tariff, 1 (low) or 2 (high){prefix}/gas: gas usage in m^3{prefix}/water: water usage in m^3
See smart_meter/smart_meter_packet.py for more information.