Modbus Provider

Modbus TCP, read-only: a device or a gateway in front of serial devices, read over a raw socket by a client this repository owns.

Issue: #1723. Type-id modbus, the third member of the industrial/ family after OPC UA and MTConnect.

This document describes what the provider does TODAY. Where a part is built and not yet reached from the product, the section says so in those words rather than describing the intention as if it were behaviour.

Write reach none: the valve, assertOutboundAllowed, admits only the read function codes and device identification on every outbound frame; there is no object edit, maintenance or transaction route

1. Overview

Modbus is a register protocol, not a database protocol. A device holds four tables of 65,536 items each - coils and discrete inputs hold single bits, input registers and holding registers hold 16-bit words - and that is the whole of its data model (MB 4.3).

Concept mapping

Modbus Studio
Unit id Container ("Unit")
Coil, discrete input, input register, holding register Object kinds
A named point of the register map Object
A 16-bit word or a single bit Value
Device identification objects (43/14) Connection details

What a reader sees

A tree of units, each holding the four kinds, each kind listing the points the register map names. With no map the kinds exist and list nothing, and the panel says why: Modbus has no discovery. No request lists what a device holds, and no register carries a name, a type or a unit.

2. Architecture

2.1 Where it sits

src/lib/db/providers/industrial/modbus/, reached through createDatabaseProvider in src/lib/db/factory.ts. No library: the client is this repository's own over the shared egress rule, as RabbitMQ's AMQP read client is.

2.2 Modules

Module What it owns
constants.ts Ports, the MBAP bounds, the read limits, the timers
pdu.ts The five requests MB-S1 allows: four reads and 43/14. Builds and bounds them
valve.ts Re-checks every outbound ADU before it reaches a socket
framing.ts Reads frames off a stream; decides what one frame is against the outstanding request
client.ts Dials (plain or TLS) and runs one exchange
session.ts Serialises exchanges, hands out transaction ids, times each one
register-map.ts Parses the user's map and refuses a malformed one
values.ts Decodes words into values, with word and byte order per point
plan.ts Groups points into as few block reads as the limits allow
objects.ts The tree, built from the map
identification.ts Reads one 43/14 answer
request.ts Parses one JSON read request, before any socket exists
index.ts The provider class and its boundaries

2.3 Why the provider carries its own client

modbus-serial 8.0.25 and jsmodbus 5.0.0 both encode writes. A client that can encode a write is a client whose read-only posture is a promise rather than a property, and the measurement in #1723 section 4.9 is why that matters: three fixture servers took FC 06 from a client that presented nothing, and over mbaps a certificate labelled "ReadOnly" wrote too. The device enforces nothing. So the encoder here names four read function codes and 43/14 with MEI type 14, and there is no function anywhere in the provider that builds a write.

2.4 The valve

The encoder cannot build a write, and the valve re-checks the bytes anyway, at the one place every ADU passes through on its way out (client.ts, immediately before socket.write). It refuses a function code outside the five, a 43 that carries any MEI type but 14, a protocol id other than 0, and an MBAP length that disagrees with the frame it is on.

A refusal there is OUR defect and not the user's: it fires on bytes this code built. It is raised before a byte is written, which is the only ordering under which the check means anything.

3. Design decisions

3.1 The register map is the data model

A point names a unit, a table, a zero-based PDU address, a type, and the orders a value wider than one register needs. Orders have no default: common stacks disagree, and a wrong order reads as a plausible number with no error at all (#1723 section 4.2), so the map states them or the point is refused.

The address is the PDU address, counted from zero, exactly what goes on the wire. Vendor documentation often numbers from one, and the two are not the same number.

3.2 No discovery, and an absent map is not an empty device

With no map, countObjects answers { unavailable } with the no-discovery sentence rather than { count: 0 }. A zero would be a claim about the device, and Modbus has no request that supports it. A map that is PRESENT and malformed is a different case and is reported as a configuration fault, because the user wrote that document and can fix it.

3.3 Blocks, and why a block stops at a hole

Point reads are planned into as few block reads as the limits allow: 125 registers or 2000 bits per request, one unit and one table per block. A block is cut wherever the map has no point, because one undefined register inside a block fails the WHOLE block with exception 02 (MEASURED).

3.4 Nothing is held open between reads

A libmodbus server serving one client at a time left a second client's read unanswered for 3003 ms while the first stayed open (#1723 section 4.7). A connection held between reads would lock out the plant's own HMI. So connect() holds nothing. It parses the map AND dials once, closing the socket at once.

The dial is there because the map alone made connect() answer for a device that is not there: MEASURED at 0 ms against a closed port. src/app/api/db/test-connection/route.ts then reports a health failure after a successful connect as a degraded success, so an address with no device answered success: true and the dialog saved the connection - which sends a reader to fix their map when the fault is the address. With the dial, a closed port is refused and the refusal names the address.

It is a dial and not a read, for the reason given in section 4.4: 43/14 is not mandatory, so a device that refuses it is one that does not know the function rather than one that is not there. And it is closed at once: what section 4.7 measured as dangerous is HOLDING a connection, not opening one twice.

3.5 A late answer is not this answer's

Transaction ids are handed out once and never reused on a connection (TCP 4.4.1.3). A frame whose id is not the outstanding one is discarded and the wait goes on; a frame that claims to answer this request and cannot - wrong unit, wrong function code, a byte count that disagrees with what was asked - ends the request. An unreadable frame ends the connection with it (MB-S4): after one there is no state in which continuing on that socket is safe.

3.6 Bounds are ours, not the device's word

The frame reader takes only the bytes a frame still needs and holds at most one complete ADU, 260 bytes. The identification walk starts at object 0 and follows Next Object Id while More Follows is 0xFF, for a bounded number of rounds and only while the next object id increases; a walk cut short returns what it has, with a warning.

3.7 A value is data

Strings decoded from registers, identification objects (the private objects 0x80 to 0xFF included) and raw words are shown as text or hex, never rendered as markup. An object's bytes are read as text only when re-encoding them gives the same bytes back: Buffer's UTF-8 decoder substitutes U+FFFD rather than failing, so bytes that are not UTF-8 come back as a string either way and the only reliable question is the round trip.

4. Connection

4.1 Configuration fields

Host, Port and the register map (section 3.1), and nothing else. The default port is 502 (IANA mbap).

4.2 There is no credential field

Modbus TCP defines no authentication: no user, no password, no token. The form offers none because there is none to offer. What protects a device is MODBUS/TCP Security or a network path you control. The connection dialog's fixed Read-only label says only that Studio has no write path on the device, and the Host field's hint says the rest: the device enforces nothing of its own, so anything else that reaches its port can still write to it.

4.3 Unit ids

1 to 255. Unit 0 is a broadcast, which carries writes only and is never answered (SL 2.2), so it is refused. 248 to 255 are reserved on a serial line; a point naming one is accepted with a warning, because a gateway may still refuse it.

4.4 TLS

MODBUS/TCP Security listens on port 802. The dial path exists (client.ts uses node:tls) and the chain and host name are checked; revocation is NOT checked, and the connection details say so in those words. MEASURED on 13 October 2026: a stapled OCSP response saying revoked still completes the connection under Node, and under Bun it never reaches the application.

Connection string

modbus has no connection string scheme, no readTls, no paste and no seed load check: every field of its row in CONNECTION_STRING is null (connection-string.ts). Its one seed-only field is registerMap (SEED_ONLY_FIELDS.modbus in connection-fields.ts): a seed carries the map to the connection, and since only the Modbus provider reads it, a seed of any other type that carries it is refused at load, naming the field.

Execution UI

The rolled-back notice names COMMIT as the keyword that keeps an open transaction, and modbus has no consent deadline, so the agent's consent card shows no deadline chip or sentence for it. Its row in EXECUTION_UI is declared in execution-ui.ts. What a tree click and Generate Query write is MODBUS_GENERATORS, the modbus row of DIALECT_GENERATORS, declared in generators.ts and read by the engine-agnostic dispatcher in src/lib/query-generators.ts.

5. Query interface

One JSON read request, in the Kafka style, in three shapes. Every shape is settled before any socket exists.

{ "read": ["voltage_l1", "frequency"] }
{ "unit": 1, "table": "holding_register", "address": 100, "count": 10 }
{ "identify": "regular" }

The schema is strict: a key the parser does not know is refused rather than ignored, because ignoring it runs a different read from the one that was written. A name is checked against the map, since a name means only what the map says it means. The protocol's bounds are not repeated in the parser - it calls checkRead, so a limit cannot pass in one file while it fails in another.

5.1 The socket, and what this section used to say

This section used to say that query() refused and getHealth() read only the map. Both now reach the device: the request is parsed, a socket is dialled for that read, the session serialises the exchanges, and the socket is destroyed in finally. Nothing is held between reads.

The order matters and is measured: a request the parser refuses costs NO connection, so a mistake in the console text never opens a socket. tests/unit/db/modbus/wired.test.ts runs the whole path against a TCP server written by hand - the frame reader, the valve, the transaction ids and the decoder all run for real - and asserts both ends: the bytes the device received are a read for the address the map names, and the rows carry the value those bytes answered with.

getHealth() dials and reads ONE point at quantity 1. A connect alone is not health (§4.10 measured a TCP connect succeeding against an absent unit behind a gateway) and neither is the socket's state (§5.1 of the issue measured ESTABLISHED for 144 seconds while no answer came). With no map there is no point to read, so health makes a PLAIN DIAL instead: a TCP connection that is opened and closed, and nothing is sent. It is deliberately not an identification read. 43/14 is not mandatory in Modbus, so a device that refuses it is a device that does not know the function rather than a device that is not there, and reporting that as a health failure would blame the wrong side.

What the dial measures is exactly this much: THE ADDRESS ANSWERED A TCP CONNECTION. Nothing was read, because no register map names a point to read, and nothing about the device's health follows from it. The sentence is written here rather than returned, because HealthInfo has no field for it: its one free-text field is databaseSize, and a sentence in a size field would be a worse answer than the unknown that is there now.

What is still absent is MODBUS/TCP Security on a real device: the TLS dial exists and has never been run against one (§12a item 3 of the specification).

5.2 SQL grammar

How this engine's statement text is read is declared once, in src/lib/db/providers/industrial/modbus/sql-grammar.ts, the modbus row of the SQL grammar registry in src/lib/db/sql-grammar/. readsSqlText is false: the console takes one JSON read request against a register map, so no span of it is SQL (#1723). The confirmation gate therefore answers from this engine's row of NON_SQL_DESTRUCTIVE_VOCABULARY (src/lib/db/providers/industrial/modbus/destructive.ts, collected in src/lib/db/destructive-commands.ts) instead of a SQL reading. Its grammar is DEFAULT_SQL_GRAMMAR, the compatibility default, since no SQL grammar of its own applies to this text. Redaction is none: a redacted statement is stored as ?, because a reader guessing where a literal ends in a language it does not read can store the literal.

5.3 SQL writing

modbus/sql-writing.ts declares how a generated statement spells a literal, a name and a bind for this engine, and it is this engine's row of SQL_WRITING (src/lib/db/sql-writing/index.ts), which the readers in src/lib/sql/values.ts and src/lib/sql/identifier.ts look up. A literal is written by literalStandard and read back by unquoteStandard: the quote is doubled and a backslash is data. A name is quoted by identifierDoubleQuoted, the SQL standard form: a double-quoted name with an inner double quote doubled. There is no placeholder (placeholder: null), so a generator quotes the value with quoteLiteral instead of emitting a bind. No generator calls quoteLiteral for Modbus: a read request is JSON and names points. Inline row editing reads a key column's kind through the shared INSTANT_TYPE_NAMES, FLOAT64_TYPE_NAMES and EXACT_DECIMAL_TYPE_NAMES of the module's inlineEdit, and binds every edit as typed.

The module's export field writes a result export's CREATE TABLE and INSERT from the shared building blocks alone: STANDARD_DDL_TYPES for the column types, NOTHING_STANDS_ALONE and NO_BARE_SPELLING, so every bare declared name is re-spelled from its family, NULL_NON_FINITE for NaN and the infinities, and binaryStandardHex for a binary cell (X'0102').

6. Object edit (#789)

No kind accepts a write of any sort, and the absence is structural rather than this version's scope. The encoder names four read function codes and device identification; there is no code in the provider that can build a write, and the valve refuses one in case there ever is.

There is also nothing a write would mean here. A point is not a row: it is a line in a document the user wrote, naming an address on a device. Editing the definition is editing the register map, which is a connection field, not an object. Editing the VALUE would be writing to a plant.

7. Security

The requirements are in docs/SECURITY.md under MB-S1 to MB-S13. The short form:

  • Read-only by construction, re-checked at the socket (MB-S1).
  • The shared egress rule applies, and a link-local address is refused by default (MB-S10).
  • The identification walk is bounded (MB-S6).
  • A value is data, never markup (MB-S13).
  • mbaps checks the chain and the host name, and not revocation, and says so.

8. Agent mode

Agent mode reads a Modbus device through queryReadOnly in index.ts. The request reader is agent-statement.ts, the reads, their bounds and their answers are agent-read.ts, the per-device pacing is agent-pacing.ts, and every other surface of an agent-mode handle is agent-surface.ts. Every claim below about a device cites the capture tests/fixtures/modbus/2.3.0/agent-boundary/boundary.json, recorded by its run.sh against a fresh container of the pinned docker/modbus fixture (pymodbus 3.12.x) and of a single-client libmodbus device built from single-client/ beside it, and written by tests/live/modbus-agent-boundary.ts. Modbus has no credential, so the capture holds none; the script refuses to write one with a credential-shaped key.

8.1 The boundary

The boundary is a structural closed table: an agent read reaches the device only through the console's reader (read.ts), whose two builders are buildRead, which sends Read Coils (01), Read Discrete Inputs (02), Read Holding Registers (03) or Read Input Registers (04), chosen by the table and never by the request, and buildIdentification, which sends Read Device Identification (43/14), over a socket whose one socket.write runs after the valve (section 2.4) re-reads the frame and refuses every other function code. So no write, diagnostic, file record or FIFO request can be sent on the agent path. agent-boundary.test.ts holds the agent's modules to naming no function code and building no frame, records every frame the agent path writes for every admitted shape (only 01, 02, 03, 04 and 43/14), and replays the capture; agent-provider.test.ts pins each read's full request frame (function code, unit, address and quantity) on a real socket.

Modbus TCP has no credential to prove read-only: the pinned fixture takes a raw write from any client. Measured raw (rawWrites, sent by the capture script on its own socket and never by Studio), function codes 5, 6, 15, 16, 22 and 23 were each answered and each changed the value it targeted, so the table is the boundary. Every request the reader refuses reached the device not at all: the capture counts the connections made through a proxy in front of the fixture, and each refusal made none (refusedBeforeSend).

8.2 What an agent request may be

One JSON object in one of the console's three shapes (section 5), read by the console's own parser and written as the console writes it:

Request Sends
{"read": ["name", ...]} the points the connection's register map names, planned into blocks as the console plans them, one read per block
{"unit": U, "table": T, "address": A, "count": N} one read of one table, optionally decoded with type, wordOrder and byteOrder
{"identify": "basic" | "regular" | "extended"} Read Device Identification from object 0, at the map's first unit as the console reads it, for at most 8 rounds

Every other request is refused before anything is sent, with the parser's sentence followed by agent mode's list of reads: text that is not JSON, any key a shape does not name (function, value, objectId), a table that is not one of the four, unit 0 (the broadcast, which carries writes only) and anything above 255, an address past 65535, a block past the end of the table, more than 125 registers or 2000 bits, a count below one, an identification level other than the three, two shapes in one object, and a point name the connection's map does not declare. A points read on a connection with no map is refused as having no map, never answered as an empty device (section 3.2). The admission, which has no connection in hand, reads a point name's shape alone; the provider reads the names against the map again before anything is sent. The admission also refuses a request longer than 4,096 characters.

A points or block read answers a number of rows its request decides, so one past the row budget is refused before anything is sent, never cut (Read-only execution exceeded the row budget: 5 rows > 4 allowed); an identification answer's rows are the device's, so they are held to the row budget once read; every result is held to the byte budget. An identification walk the device was still continuing after 8 rounds is refused rather than answered in part, where the console answers what it has with a warning (section 3.6). A failure is worded by its category and quotes nothing the device sent: the device's silence for one request's 3,000 ms, its exception by code with this provider's sentence for that code, an answer that cannot be read as an answer to this read, a value the map's declaration cannot decode, an address nothing answers, and settings the egress rule refuses.

8.3 Pacing

A device that serves one client at a time answers nobody else while a client holds its connection. Measured on the single-client device (lockout.singleClient): a second client that sent a read while a first held its connection for 2000 ms was answered 2000 ms later, 0 ms after the first closed, and a client that dialled after a read closed was answered in 0 to 1 ms; one agent read held its connection for 1 ms (agentReadHoldMs). So the lockout is the hold and nothing after it. The pinned fixture cannot show it: it answered a second client in 0 ms while the first held its connection (lockout.pymodbus), as docker/modbus/README.md records.

So, on the agent path:

  • nothing is held open between reads: each read opens its own socket and destroys it before it settles, as the console does (section 3.4);
  • agent reads of one device never overlap, across every run and every connection of the server process, because the lanes are kept once per process, in a global every copy of the provider's module shares (Next.js loads the module once for the route handlers and again for instrumentation, which resumes agent runs), rather than on the cached provider; a lane is the device's host and port, never the unit, since a gateway serves every unit behind it over one connection, and a host written as a name and as an address is two lanes;
  • a fixed gap of 1,000 ms (MODBUS_AGENT_DEVICE_GAP_MS), a chosen value rather than a measured one since the measured lockout is the hold itself, follows each agent read, measured from the moment its socket was destroyed, so the next one cannot queue straight behind it and leave the plant's own client no turn: at the measured hold that leaves the device free for all but about a thousandth of the time an agent spends on it; the capture's two agent reads sent at once through the server's pacer never overlapped (maxOpen 1) and the second dialled 999 ms after the first closed, as the proxy in front of the device heard it (pacing);
  • one run sends at most 64 device requests (MODBUS_AGENT_RUN_REQUESTS), each read charged before it dials with the most it may send, one per planned block, one for a block, and 8 for identification, to the run's own ledger (ReadOnlyStatementBudget.readAllowance, one unit per device request), which a resumed run carries; a read that would pass the bound is refused before anything is sent, and a budget that carries no run is refused.

A read's time budget starts when it is asked for and covers its wait for its turn, the gap and the read itself. Its execution time, the figure the agent rail and the run's database time show, is its own time on the device, from its turn to its socket's close: the wait and the gap are Studio's, and a read of a device that answers in a millisecond is never shown as taking the gap. A read whose turn would come after its budget is refused at once in Studio's words, Read-only execution exceeded the time budget: the read waited ..., and keeps its place in the order until the read ahead of it ends, so the read behind it still never overlaps the one in front; a read still running at its deadline is refused in Studio's words and its socket destroyed. Neither is ever worded as the device's failure, and the device's silence is never worded as Studio's budget. A read that fails or is abandoned frees its lane when its own deadline passes at the latest, since its socket is destroyed by then; a dial still in flight at the deadline is awaited, for at most its own 3,000 ms bound, and destroyed once it opens before the lane is freed.

8.4 Values, and what each path reads

Values are the device's own readings, and Modbus has no credential to withhold, so agent mode answers them exactly as the console renders them (section 3.7): coils and inputs as booleans, registers as words and as values decoded under the register map's declaration, and identification objects, the private objects 0x80 to 0xFF included, as text only when their bytes round-trip as text with no control byte and as hex otherwise. Every result reaches the model inside the untrusted-content fence, whose closing marker a device's text cannot spell. The register map is the connection's own configuration, and its point names reach the model as object names.

Path Handle What it reads
Investigation reads agent read-only profile one request of section 8.2, paced as section 8.3 says
Investigation grounding, plan-mode grounding and the operations workflow's inventory either agent profile the register map's units and points by name, which sends nothing to the device; with no map the provider declares through inventoryNeedsConfiguration that nothing can be listed, with its reason that the connection keeps no register map, so the grounding names every kind as unlisted with that reason and says nothing was listed, and the rail reads "no tables listed" with the reason, never that the device reported none
Connect and health either agent profile the console's own dial, and health's one-point read (a dial alone with no map), each taking its turn on the device's lane and waiting at most 9,000 ms for it
Console, overview, performance, storage, session, slow-query, table and index readings either agent profile nothing: each is refused with its reason, never answered with Studio's own figures or an empty reading

8.5 Agent language pack

Statement-language family: modbusread. Overlay: src/lib/agent/languages/modbusread/engines/modbus.ts, with its client row in src/lib/agent/languages/modbusread/engines/client.ts. The agent reads it through runServerPack and agentEnginePack. Both overlays are empty, so the engine resolves to the modbusread family pack itself. The modbusread statement-language family has no dialect-bound member. This overlay overrides no Shared member, so every Shared member is the modbusread statement-language family's own. The family offers the investigation workflow, through run_read_query with one request, and the operations workflow; it offers no query optimization or database assessment, since a device has no plan and no profile, and no data analysis, whose tools assume a store of records, and no workflow hands an answer to the editor. The workflow classifier offers the model only these two. Plan mode's safety strip is the family's own (posture.plan in client.ts): "the register map grounds it; opening the connection dials the device, and no request is sent to it", because the grounding reads the map and sends the device nothing, while the acquisition's connect dials the device's port and closes it again, so the shared strip's "nothing else reaches the database" would not be true here. The editor language id stays modbus, and the fence alias modbusread names this engine. A pack does not open agent mode: execution is gated by AGENT_EXECUTION_ENGINES and the execution-profile check. No MCP tool runs a Modbus request: the family declares no MCP facet, MCP_EXPOSABLE.modbus and MCP_STATEMENT_READ.modbus are false (B160), and READ_ONLY_ENFORCED.modbus is unchanged.

Migration DDL

MODBUS_MIGRATION_DDL is what the schema-diff migration generator writes for modbus, read through migrationDdlFor in src/lib/db/migration-ddl/. It declines the whole diff: refusal is the one line the migration prints after its header, in place of any DDL, and transactionWrapper is null. What a register means is the device vendor's, written down in the user's register map, so there is no table DDL to wrap either (#1723).

The refusal reason it prints, verbatim:

  • "A Modbus register has no column definition anywhere: the device holds 16-bit words and single bits with no name, no type and no unit, and what gives them meaning is the register map the user wrote, so there is nothing a client could change here."