Status: frozen on 11 July 2026. No experiment in this bundle distinguishes OPH from standard quantum mechanics. The code, derived legacy summaries, and complete issue
#509receipts are retained as an engineering and reproducibility archive. New OPH-evidence runs on quantum-cloud hardware are paused until OPH supplies a quantitative prediction that differs from standard quantum mechanics.
This directory is the public code-and-data archive for the completed IBM Quantum Cloud OPH-motivated engineering experiments.
It contains:
programs/: runnable preflight, sealing, execution, harvesting, and analysis scriptsqc_data/: representative derived JSON summaries from the legacy hardware runsprotocols/: frozen or pre-hardware experimental protocol specificationstests/: mandatory finite-kernel tests and optional Qiskit/Aer circuit tests
The bundle contains two scientifically different kinds of experiment.
- The original Stage 1,
Z_3,Z_5, andS_3runs prepare states whose mathematical pattern is already specified, then ask whether a real QPU can preserve and read that pattern. These are state-preparation, readout, and layout-consistency tests. - The issue
#509benchmark starts from ordinary basis states and generates its output through a mid-circuit record and conditional feedback. It was preregistered, blinded, run on a development QPU and a held-out QPU, and analyzed before the semantic reveal was opened. Its complete receipts are underruns/issue_509_20260711_v2/.
The second kind is stronger evidence for the engineered controller claim because the bounded patch reads its own local state, writes a record, uses that record to choose a repair move, and publishes the evidence needed to audit the process. It is not evidence for OPH over unrestricted quantum mechanics. Standard quantum mechanics predicts every programmed circuit in this bundle.
The archived legacy summaries describe 10 provider jobs, 294 circuit
instances, and 400,384 shots. The blinded benchmark adds 14 jobs, 3,104
circuits, and 606,208 shots. Those totals do not imply equal evidential weight:
the legacy qc_data/ files mostly preserve derived metrics rather than every
provider count, whereas the blinded run preserves the complete raw joined
counts, job journals, commitments, and replayable analysis.
“Strong evidence” is meaningful only after stating what the evidence is for. This README uses four practical levels.
- Sanity check: verifies that an encoding, analysis, or readout behaves as expected. It is useful for finding mistakes but weak as a theory test.
- Supportive hardware consistency: repeats a predicted pattern on real hardware, sometimes on more than one chip, but the target was prepared in the state or an important choice was made after looking at data.
- Confirmatory implementation test: freezes the target, controls, layouts, analysis, and failure rule before a blinded held-out run. This can strongly test the stated device or controller claim.
- Theory-discriminating test: competing physical theories make different predictions for the same intervention. None of the experiments in this directory reaches this level for OPH versus standard quantum mechanics.
The immediate engineering claim and the broad OPH claim therefore receive different assessments:
| Experiment | Immediate outcome | Strength for the immediate claim | Strength for OPH as a physical theory |
|---|---|---|---|
| Stage 1 recoverability | Legacy summaries report lower conditional dependence and higher recovery fidelity for structured states on two QPUs | Archived consistency report; measured rows cannot be independently revalidated from the retained data | None as a discriminator; the ordering is designed into QM-prepared states |
Z_3 heat-kernel check |
Two independently decoded nontrivial states gave nearly the same heat time at all three prepared points | Strong sanity check | None as a discriminator; QM predicts the directly prepared distribution |
Z_5 golden-ratio check |
Several runs landed near phi^2, but the values spread from 2.407 to 2.878, and the high-shot point was below the exact target |
Mixed supportive consistency | None as a discriminator; QM predicts the encoded amplitude ratio |
S_3 nonabelian check |
The base layout missed 2; reversing the physical qubits moved the result near 2, and a repeat stayed near 2 |
Useful layout diagnostic | None as a discriminator; QM predicts the prepared state and measurement |
| Blinded record-gated repair | Passed every frozen primary null on both the development and held-out QPUs | Strong confirmatory evidence for the programmed self-reading repair implementation | None as a discriminator; QM predicts measurement, records, and feedback |
| Secondary dimension-exponent test | Identifiable nonabelian spectra favored kappa = 1; abelian negative controls correctly had zero separation |
Supportive diagnostic evidence | None as a discriminator; it checks a programmed stationary-law convention |
Imagine three neighboring pieces of a system, called A, B, and C. If B carries almost all of the information needed to connect A with C, then the full state can be approximately recovered from AB by acting on B. The benchmark measures this with:
- conditional mutual information (CMI): lower is more locally Markovian;
- Petz recovery fidelity (squared Uhlmann convention): closer to
1means a standard recovery map, computed from the reconstructed state, rebuilds the full three-part state more accurately from overlapping local pieces.
The circuit family contains three deliberately structured states, one
fixed-depth random control, and one GHZ control. Full three-qubit Pauli
tomography reconstructs each density matrix. Each tomography circuit uses 512
shots. The Petz recovery is an offline calculation on that reconstruction; the
QPU does not execute a Petz-recovery circuit. The random control, seed 2, was
chosen from ten candidate random circuits because it had the largest ideal
CMI. The test was run on ibm_marrakesh and independently on ibm_fez.
The frozen derived summaries report the following ordering for
structured_theta_0.00 and the controls. These historical values are retained
as reported; the measured rows have not been independently revalidated:
| Backend | CMI: structured | CMI: random | CMI: GHZ | Recovery fidelity: structured | Random | GHZ |
|---|---|---|---|---|---|---|
ibm_marrakesh |
0.231 |
0.389 |
0.947 |
0.930 |
0.865 |
0.607 |
ibm_fez |
0.150 |
0.499 |
0.917 |
0.948 |
0.812 |
0.645 |
The archived summaries record true for all three qualitative fingerprint
checks on both backends. The provider jobs are d6t4da6sh9gc73di7720 and
d6t4ejngtkcc73cm8l6g; the public derived reconstruction summaries are in
qc_data/stage1/.
The archived Fawzi--Renner bounds use root fidelity while these recovery measurements use squared fidelity. See the archive correction note for the conversion and the theorem's scope over possible recovery channels.
The measured rows are archived consistency reports. Complete tomography counts and reconstructed density matrices were not retained, so the corrected analysis cannot independently revalidate their CMI or recovery values. The recovery audit found that the former pipeline could silently repair invalid states, erase rare sectors and accept incomplete tomography. The numerical impact on these archived rows cannot be determined from the retained summaries.
The repaired pipeline validates complete count records, preserves resolved positive support and saves acquired evidence before analysis. Circuit references and complete synthetic-count controls can be replayed; unresolved Petz support leaves valid CMI available and marks recovery metrics unavailable. Those controls validate the software, while the historical measured rows remain unrevalidated. No formal uncertainty test was attached to those rows, and tomographic correction can affect nonlinear quantities such as CMI and fidelity.
The prepared ordering does not distinguish OPH from quantum mechanics. The structured circuits were constructed to have lower ideal CMI, and the random control was selected from a candidate family rather than held out.
Z_3 is a three-position cycle. The experiment prepares a heat-kernel-shaped
probability distribution at three declared heat times, t = 0.3, 0.6, and
0.9. Its two nontrivial states should encode the same heat time. Reading each
one independently therefore gives a simple cross-check: if the two inferred
times disagree badly, the encoding or readout is not trustworthy.
The run used 4,096 shots per prepared time on ibm_marrakesh, with one unused
two-qubit code retained as leakage rather than discarded.
Prepared t |
Inferred from state 1 | Inferred from state 2 | Absolute difference | Leakage |
|---|---|---|---|---|
0.3 |
0.3233 |
0.3091 |
0.0142 |
0.098% |
0.6 |
0.6164 |
0.6130 |
0.0034 |
0.073% |
0.9 |
0.9174 |
0.9131 |
0.0043 |
0.049% |
The two decodings agree closely at all three points. The provider job is
d6t4ic790okc73et0n4g, with derived probabilities and bootstrap intervals in
qc_data/z3/.
This is a strong sanity check for the small encoding and analysis path. It is not evidence for OPH over QM: the heat-kernel probabilities were placed in the initial state, both inferred times come from that same prepared state, and the check used one backend. The analysis renormalizes the probabilities inside the three valid codes after separately reporting the very small invalid- code leakage. That is reasonable for checking the encoded sector, but it is another reason not to read this as an independently generated law of nature.
Z_5 is a five-position cycle encoded in three qubits. For the chosen spectrum,
two logarithmic probability gaps are supposed to have the ratio
phi^2 = 2.6180339887.... The experiment prepares the corresponding amplitudes,
measures them, and reconstructs that ratio. A sixth, seventh, or eighth code is
counted as leakage.
The target neighborhood was reproduced several times, but not with the stability expected of a new exact-number measurement:
| Run | Shots per point | Ratio at t=0.3 |
t=0.6 |
t=0.9 |
|---|---|---|---|---|
ibm_marrakesh, seed 11 |
4,096 | 2.597 |
2.738 |
2.579 |
ibm_marrakesh, seed 17 |
4,096 | 2.453 |
2.878 |
2.649 |
ibm_fez, seed 17 |
4,096 | 2.726 |
2.407 |
2.461 |
ibm_marrakesh, high-shot t=0.9 |
32,768 | n/a | n/a | 2.550 |
The observed ratios range from 2.407 to 2.878 around the target 2.618.
The high-shot t=0.9 bootstrap interval was approximately [2.492, 2.602],
which sits slightly below the exact target. Leakage remained between about
0.22% and 1.03%. Seven of the nine ordinary 4,096-shot intervals included
the target; the separate high-shot interval did not. Provider job IDs and the
full per-point intervals are in qc_data/z5/.
The repeated near-target values are supportive hardware consistency for
preparing and reading the intended five-state family. The spread, including a
high-shot interval that excludes the exact value, makes the evidence mixed for
an exact hardware ratio. More importantly, the target is encoded directly in
the prepared amplitudes. The bootstrap intervals quantify finite-shot
variation, not calibration drift, model choice, or other systematic error.
This is not an independent derivation of phi^2 by the QPU and provides no
OPH-versus-QM evidence.
S_3, the six permutations of three objects, is the smallest nonabelian group.
Its three reduced representation sectors are encoded in two qubits. After
accounting for the two-dimensional standard representation, the two measured
logarithmic gaps should have ratio 2. This is again a prepared-state test,
but it also probes whether assigning the two logical sector bits to different
physical qubits biases the answer.
At prepared t = 0.6, 16,384-shot jobs on ibm_marrakesh gave:
| Physical layout | Raw ratio | Readout-mitigated ratio | 95% bootstrap interval after mitigation |
|---|---|---|---|
base [7, 8] |
1.854 |
1.872 |
[1.807, 1.928] |
reversed [8, 7] |
2.035 |
2.030 |
[1.966, 2.100] |
The base layout missed the target. Reversing the same two physical qubits moved
the ratio across the target neighborhood. A separate seed-17 confirmation on
the reversed layout measured 2.066, with interval [1.995, 2.127] and
0.012% leakage. The jobs and assignment matrices are in
qc_data/s3/.
This is a valuable hardware-bias diagnostic: it shows that the sector-to-
qubit map materially changes the extracted ratio, and the archived summaries
make that dependence visible. It is not an OPH-versus-QM test. The
reversed layout was investigated after the base-layout bias was observed, so
landing near 2 is partly a post-observation layout result. The later repeat
supports the diagnosis but does not retroactively blind the layout choice. All three
jobs used the same IBM backend, the same physical-qubit pair, and essentially
the same operating point. The bootstrap also treats the fitted assignment
matrix as fixed, so its uncertainty is not propagated into the interval.
The older tests ask whether a target already placed in an initial state survives the hardware. This benchmark asks whether the device can generate a repair decision from a record created during the circuit. “Generative” is used in that control-system sense: the output is generated by measurement and feedback. It does not refer to generative AI.
Each dynamic circuit uses three qubits for a finite mismatch state and one decision qubit. It:
- starts from an ordinary computational-basis state;
- applies a balanced lazy disturbance;
- reads the disturbed state into a mid-circuit record;
- decides whether a proposed move reduces the mismatch;
- records that decision;
- applies the repair only when the decision says it should; and
- records the final state.
That is the observer-like technology claim in concrete form: a bounded patch has local state and a boundary, reads itself, writes a record, feeds the record back into a repair move, and emits a public audit trail.
The primary repair arm is compared with matched lazy heat that ignores the record, a delayed record, a shuffled record, an inverted decision, a state-preparation-only explanation, a calibrated-noise model, and a mixture of 256 possible label/layout maps. Invalid codes and failed feedback stay in the outcome table; they are never postselected away.
The state-preparation-only null is especially important. It preserves the final-state histogram and the joint disturbed-state/decision histogram, but breaks the temporal link connecting the record, decision, and later repair. Beating it therefore shows that matching static before-and-after histograms is not enough to explain the observed joint process.
Before hardware submission, the catalog froze every circuit, shot count,
backend policy, physical layout, null model, leakage rule, analysis threshold,
and exclusion rule. Semantic group labels, controller identities, backend
roles, and layout identities were hidden behind opaque IDs. ibm_fez was run
as the development slot. Only after all its jobs completed was the held-out
ibm_kingston slot submitted. The blind report was written and file-hashed
before the private reveal was opened.
- 14 IBM Runtime jobs completed: 3,104 circuits and 606,208 shots.
- Every submitted job and expected row was included, with no dropped or postselected shots.
- After unblinding, the reveal commitment and all 3,104 logical-circuit hashes verified.
The primary statistic compares the probability of all observed joint outcomes
under record-gated repair with their probability under each frozen null. A
positive log-likelihood ratio favors repair; larger values mean greater
separation. The required thresholds were log(10) per backend and log(100)
pooled.
| Frozen null | ibm_fez log ratio |
held-out ibm_kingston |
Pooled |
|---|---|---|---|
| lazy heat, which ignores the record | 136,738.537 |
141,443.849 |
278,182.386 |
| delayed record | 77,145.222 |
78,954.396 |
156,099.617 |
| shuffled record | 93,252.706 |
96,396.875 |
189,649.582 |
| inverted decision | 275,461.330 |
284,142.447 |
559,603.778 |
| state preparation only | 99,891.886 |
103,598.342 |
203,490.228 |
| calibrated noise | 171,961.767 |
180,409.442 |
352,371.209 |
| mixture of 256 label/layout maps | 5.545 |
5.545 |
5.545 |
The smallest entry, 5.545, corresponds to an ordinary likelihood ratio of
about 256. The preregistered reference mapping was also the unique best one
among the 256 candidates. The much larger process ratios accumulate evidence
over many shots and many deliberately distinct circuit variants; they should
not be compared directly with a single small laboratory measurement.
The run also passed all frozen quality gates:
- the largest four-bit basis error was
3.516%onibm_fezand2.930%onibm_kingston, below the15%limit; - pooled Cayley leakage was
3.362%and1.189%, below the10%limits; - the worst individual circuit had
19.792%leakage, retained in the data and below the separate25%catastrophic limit; - every comparison still passed when the frozen contamination fraction was
varied from
4%through15%, around the central8%model; and - the complete primary S3 transition law had zero violations in a simultaneous 99% prediction envelope covering 55,296 locked outcome cells.
That last number counts the many cells in the locked transition table, not 55,296 independent experiments. “Zero violations” means that none fell outside the tolerance calibrated for the whole family at once.
The full result, jobs, raw counts, checksums, and exact replay commands are in
runs/issue_509_20260711_v2/.
The very large log-likelihood ratios need context. They accumulate over many shots and many sharply separated, nearly deterministic circuit variants. They show that the hardware data match the programmed conditional controller far better than the listed frozen controllers. They are not odds that OPH is true, and they are not Bayes factors.
This is the strongest evidence in the directory for its immediate implementation claim. It is preregistered, blinded, multiplicity-corrected, held out on a second QPU, fail-closed on calibration and leakage, and fully receipt-backed. It strongly supports the statement that IBM hardware realized the programmed finite self-reading repair instrument and that this instrument outperformed the restricted nulls. The held-out chip is a real replication barrier, but both chips came from one provider and one campaign, so this does not yet establish robustness across providers, hardware generations, or time.
It does not support the stronger statement that OPH beat standard quantum mechanics. Unrestricted quantum mechanics includes measurement, classical records, and feedback, so it predicts the same programmed instrument. The run also says nothing direct about OPH relativity, Standard Model, cosmology, or ontology claims.
The companion Metropolis--Hastings circuits test three programmed stationary-
law conventions. kappa = 1 gives one factor of representation dimension,
kappa = 0 removes that factor, and kappa = 2 uses a squared or Plancherel-
like factor. S3, A4, and a seeded random spectrum contain unequal dimensions,
so the choices can be distinguished. Z3 and Z5 have only one-dimensional
sectors, so all three choices must be identical; those are negative controls.
On the two backend slots, the identifiable S3, A4, and seeded-random families
favored the programmed kappa = 1 law over kappa = 0 and kappa = 2. The Z3
and Z5 negative controls returned exactly zero log-likelihood separation, as
required. Fourteen Holm-corrected secondary goodness-of-fit tests produced no
rejection at family alpha 0.01.
| Pooled family | log ratio: kappa=1 over kappa=0 |
log ratio: kappa=1 over kappa=2 |
|---|---|---|
| S3 | 46.216 |
83.635 |
| A4 nonabelian decoy | 28.276 |
14.092 |
| seeded random nonabelian decoy | 189.026 |
926.073 |
| Z3 abelian negative control | 0.000 |
0.000 |
| Z5 abelian negative control | 0.000 |
0.000 |
This is supportive diagnostic evidence that the circuit family and analysis correctly distinguish the dimension conventions when they are identifiable and refuse to do so when they are not. It did not select the primary verdict, and it does not derive nature's stationary law or independently confirm OPH.
For every experiment above, standard quantum mechanics predicts the same probabilities as the advertised OPH-motivated target:
- Stage 1, Z3, Z5, and S3 place the target structure into a state prepared with standard quantum gates, then measure it with standard quantum readout.
- The generative benchmark is a standard dynamic quantum circuit: measurement creates a classical record and standard conditional feedback acts on that record.
- Its impressive likelihood ratios compare the implemented controller with deliberately restricted controller and noise nulls. They do not compare an OPH probability law with a different quantum-mechanical probability law.
This is a missing-model-contrast problem, not a statistical-power problem. More shots, qubits, backends, or elaborate blinding would make the engineering replication stronger but would not create evidence that separates OPH from quantum mechanics. Hardware noise and provider calibration would matter once a specific deviation existed, but they are not the reason for the present freeze: there is currently no different OPH number to measure.
The hardware program may be reopened only after a discriminator proposal provides all of the following before platform selection or data collection:
- a source-closed observable for which OPH and standard quantum mechanics give different numerical predictions;
- the sign and magnitude of the predicted difference as a function of the controlled experimental parameters;
- a nuisance and calibration model showing that the difference is identifiable above the proposed platform's noise floor;
- an audit against existing experimental bounds, especially matter-wave, optomechanical, collapse-model, gravitational-response, and spontaneous- emission constraints when relevant; and
- a preregistered decision rule, power calculation, and public evidence plan.
Until that gate is met, maintenance, security fixes, and exact replay of the archive are welcome, but no new IBM Quantum run should be presented or funded as evidence for OPH over standard quantum mechanics.
programs/ibm_runtime_common.pyShared IBM Runtime helper utilities.programs/check_ibm_setup.pyAuth and backend-discovery verifier.programs/discrete_heatkernel_test.pyZ_3,Z_5, andS_3reduced-sector runner.programs/s3_diagnostic_bundle.pyS_3layout and readout diagnostic bundle.programs/stage1_markov_fingerprint.py3-qubit Markov / recoverability benchmark. Its finite recovery audit requires complete tomography data, retains resolved positive support and distinguishes the fixed Petz channel from an optimal-recovery fidelity bound. New summaries retain raw counts and disclose the explicit tomographic state correction. The estimator certifies positivity of its returned entries; if ordinary reconstruction loses it, outward Gram rounding restores it with a reported numerical bound. That bound does not certify statistical uncertainty. The runner savesacquired_counts.jsonwith count mappings and run metadata immediately after sampler return, before numerical analysis. Unresolved Petz support leaves valid CMI available; recovery metrics and dependent checks are explicitlynull, withpetz_statusand a reason in each row. Use a separate output directory for each run. Existingacquired_counts.json,summary.jsonorsummary_pretty.txtcauses refusal before sampling, so a failed rerun cannot mix acquired counts with a previous success report.programs/generative_repair_kernel.pyPure finite-matrix implementation of the record-gated Cayley repair kernel, the matched open-loop heat null, and the dimension-exponent diagnostic.programs/record_gated_cayley_circuits.pyLocal dynamic-circuit preflight for the self-reading repair instrument. It contains no IBM submission path.programs/generative_repair_circuits.pySecondary Metropolis--Hastingskappa = 0, 1, 2diagnostic circuits, including mandatory abelian non-identifiability controls.programs/blind_preregister.pyOpaque circuit catalog, private commit/reveal payload, and digest verifier.programs/blind_preregister_orchestrate.pyTwo-phase production seal: catalog precommitment followed by an analysis-lock binding and atomically committed public/private artifacts.programs/cayley_blind_likelihood_analysis.pyFrozen joint-process conditional likelihood ratios, contamination sensitivity, calibration/leakage gates, and blinded verdict logic.programs/record_gated_cayley_runtime.pyExplicit role-scoped IBM plan, submit, and harvest path with append-only hash-chained journals.programs/runtime_analysis_packet.pyFail-closed conversion of the complete two-role runtime journals into the blinded analysis packet.protocols/BLINDED_GENERATIVE_REPAIR_KERNEL.mdClaim boundary, exact predictions, blinding contract, nulls, and failure rule for the issue#509benchmark.runs/issue_509_20260711_v2/Public manifest, committed reveal, raw provider count journals, sealed blind packet/report, job receipts, checksums, and the completed hardware result.qc_data/README.mdIndex of the representative legacy derived summaries.
The exact frozen contract is in
protocols/BLINDED_GENERATIVE_REPAIR_KERNEL.md,
and the public run README gives the hashes and end-to-end replay commands. Each
dynamic variant used 192 shots per backend slot; separate four-bit calibration
circuits used 512 shots per prepared code. The calibration circuits are
validity diagnostics, not a factorized correction applied to the feedback
data. Development had to finish before held-out submission, and both roles
remained bound to the same sealed catalog and analysis lock.
Create the pinned optional environment:
python3 -m venv /tmp/oph-ibm-quantum
/tmp/oph-ibm-quantum/bin/python -m pip install -r code/ibm_quantum_cloud/requirements-ibm.txtRun the pure finite-kernel and optional circuit tests:
python3 -m pytest -q code/ibm_quantum_cloud/tests/test_generative_repair_kernel.py
/tmp/oph-ibm-quantum/bin/python -m pytest -q \
code/ibm_quantum_cloud/tests/test_generative_repair_kernel.py \
code/ibm_quantum_cloud/tests/test_record_gated_cayley_circuits.pyGenerate local validation receipts without credentials or hardware submission:
python3 code/ibm_quantum_cloud/programs/generative_repair_kernel.py \
--json-out /tmp/oph-generative-kernel-validation.json
/tmp/oph-ibm-quantum/bin/python \
code/ibm_quantum_cloud/programs/record_gated_cayley_circuits.py \
--model s3 \
--protocol record_gated \
--shots 192 \
--json-out /tmp/oph-s3-record-gated-preflight.jsonThese local receipts validate an engineered record-conditioned process against
frozen open-loop and stationary-law nulls. The hardware workflow additionally
requires the two-phase seal, role-scoped sequential execution, complete
hash-chained journals, blind conditional-likelihood report, and verified
reveal required by the issue #509 acceptance protocol.
A passing hardware result supports only the realization of a blinded finite self-reading repair instrument against its frozen controller, label, noise, and decoy nulls. Standard quantum mechanics predicts the programmed instrument, so the result cannot distinguish OPH from unrestricted quantum mechanics and does not establish an OPH vacuum, relativity, Standard Model structure, or cosmology.
These commands are retained for reproducibility and maintenance. Their presence does not reopen the frozen OPH-evidence campaign.
The credential file is not part of this repo. The scripts accept either a raw IBM Cloud API key or a local note file with a line of the form:
IBM cloud API key: <YOUR_API_KEY>
Pass it explicitly with --credentials-file if it is not in the current working directory.
Example commands:
python3 code/ibm_quantum_cloud/programs/check_ibm_setup.py --credentials-file /path/to/IBM_cloud.txt
python3 code/ibm_quantum_cloud/programs/discrete_heatkernel_test.py \
--group z3 \
--mode hardware \
--backend ibm_marrakesh \
--shots 4096 \
--outdir code/ibm_quantum_cloud/qc_data/z3/rerun_example \
--credentials-file /path/to/IBM_cloud.txt
python3 code/ibm_quantum_cloud/programs/s3_diagnostic_bundle.py \
--mode hardware \
--backend ibm_marrakesh \
--t-value 0.60 \
--shots 8192 \
--use-best-pair-layout \
--outdir code/ibm_quantum_cloud/qc_data/s3/rerun_example \
--credentials-file /path/to/IBM_cloud.txt- The legacy JSON exports keep original job IDs and the reported derived metrics, but account-specific instance CRNs are redacted in the public copy.
- Complete provider count dictionaries were not archived for most Stage 1, Z3, Z5, and direct S3 runs. The S3 layout summaries retain target counts and fitted assignment matrices, but not every calibration count dictionary.
- The issue
#509v2 directory is different: it retains the complete raw joined counts for all 3,104 circuits, provider metadata, hash-chained journals, the blind packet and report, and everything needed for exact public replay.
This code and data bundle is part of the OPH public repository. See the main LICENSE.